HRA(H) Relay
1.COIL DATA
1-1.Nominal Voltage
1-2.Coil Resistance
1-3.Operate Voltage
1-4.Release Voltage
1-5.Nominal Power Consumption
2.CONTACT DATA
2-1.Contact Arrangement
2-2.Contact Material
2-3.Contact Rating
2-4.Max. Switching Voltage
2-5.Max. Switching Current
2-6.Max. Switching Power
2-7.Contact Resistance ( Initial )
2-8.Life Expectancy
Electrical
Mechanical
3.GENERAL DATA
3-1.Insulation Resistance
3-2.Dielectric Strength
3-3.Operate Time
3-4.Release Time
3-5.Temperature Range
3-6.Shock Resistance
3-7.Vibration Resistance
3-8.Weight
3-9.Safety Standard
4.DIMENSIONS ( in mm )
3 VDC to 24 VDC
Refer to Table 1
Refer to Table 1
Refer to Table 1
330 to 450 mW
1 Form C
AuAg
1A 24 VDC / 120VAC
30 VDC / 120 VAC
2A
120 VA , 24W
100 m¦¸. at 6 VDC 1A
100,000 operations at nominal load
10,000,000 operations
Min.100M¦¸ at 500 VDC
500VAC , 1min between open contact
500VAC , 1min between contacts and coil
Max. 6ms
Max. 4ms
-25 to +70 ¡æ
15G
10-55 Hz , Amplitude 1.5mm
1.7 gr.
UL NO. E164730
HRA
¡¡
5.ORDERING CODE
H-
|
|
|
|
|
|
|
|
|
|
|
|
S
|
|
DC5V
¡¡¡¡
|____ _________
|_____¡¡NOMINAL VOLTAGE:
DC3V , DC5V , DC6V , DC9V , DC12V , DC24V
¡¡ENCLOSURE
S ----WASHABLE
COIL
NOMINAL
mW
450
330
380
|_____ ________ _________
|
|
|_____ ________ _________ _________ ¡¡TYPE
¡¡
COIL
NIL ---- STANDARD TYPE
H ------- HIGH SENSITIVE TYPE
6.COIL DATA CHART
ORDERING CODE
HRA-S DC3V
HRA-S DC5V
HRA-S DC6V
HRA-S DC9V
HRA-S DC12V
HRA-S DC24V
HRAH-S DC3V
HRAH-S DC5V
HRAH-S DC6V
HRAH-S DC9V
HRAH-S DC12V
HRAH-S DC24V
COIL
NOMINAL
VDC
3
5
6
9
12
24
3
5
6
9
12
24
COIL RESISTANCE
¦¸ +/- 10%
20
55
80
180
320
1280
28
75
110
250
440
1560
OPERATE
VOLTAGE
VDC
2.4
4.00
4.80
7.20
9.60
19.20
2.40
4.00
4.80
7.20
9.60
19.20
RELEASE
VOLTAGE
VDC
0.15
0.25
0.30
0.45
0.60
1.20
0.15
0.25
0.30
0.45
0.60
1.20
7.HRA(H) CHARACTERISTIC DATA
Table 1
¡¡
¡¡
Life Curve
¡¡
Maximum Switching Power
¡¡
¡¡
¡¡