logo资料库

NI USB6501的data sheet.pdf

第1页 / 共8页
第2页 / 共8页
第3页 / 共8页
第4页 / 共8页
第5页 / 共8页
第6页 / 共8页
第7页 / 共8页
第8页 / 共8页
资料共8页,全文预览结束
Requirements and Compatibility Ordering Information Detailed Specifications For user manuals and dimensional drawings, visit the product page resources tab on ni.com. | | Technical Sales (866) 531-6285 orders@ni.com | Pinouts/Front Panel Connections Last Revised: 2014-11-06 07:14:35.0 NI USB-6501 Low-Cost USB Digital I/O Device Small, portable digital I/O device 24 digital I/O lines, one 32-bit counter Overvoltage protection, 8.5 mA current drive Full-speed USB (12 Mbit/s) bus interface Built-in screw terminals with removable connectors for easier connectivity OEM version available with 34-pin IDC mass termination connectivity Overview The NI USB-6501 is a portable digital I/O device that provides reliable data acquisition and control at a low price. With plug-and-play USB connectivity, the USB-6501 is simple enough for home/academic applications but robust and versatile enough for laboratory/industrial applications. The board-only version is ideal for embedded OEM applications. Requirements and Compatibility OS Information Linux® Mac OS X Windows 2000/XP Windows 7 Windows Vista x64/x86 Driver Information NI-DAQmx Software Compatibility ANSI C LabVIEW LabWindows/CVI Measurement Studio Visual Basic Visual Studio Visual Studio .NET Back to Top Back to Top Comparison Tables Product Bus Digital I/O Lines Counters Current Drive Logic Level Industrial Feature Set NI 6501 USB 24 1 8.5 mA 5 V TTL/CMOS No Back to Top Application and Technology Hardware The USB-6501 is a full-speed USB device that provides 24 DIO lines and a 32-bit counter. The 24 digital lines are arranged in three ports: P0.<0..7>, P1.<0..7>, and P2.<0..7>. P2.7 can also function as a 32-bit counter. You can individually program each of the USB-6501 DIO lines as a DI or DO line and use the DIO lines to monitor or control digital signals. All samples of the DI lines and updates of the DO lines are software-timed. The default configuration of the USB-6501 DIO ports is open-drain for 5 V operation with an 1/8 www.ni.com
onboard 4.7 kΩ pull-up resistor. You can add an external, user-provided, pull-up resistor to increase the source current drive up to 8.5 mA per line. Each DIO signal is protected against overvoltage, undervoltage, and overcurrent conditions as well as ESD events. At system startup and reset, the hardware sets all DIO lines to high-impedance inputs. The data acquisition device does not drive the signal high or low. Each line has a weak pull-up resistor connected to it. You can configure P2.7 as the source for a 32-bit counter. In this mode, the device counts high to low transitions (falling edges) on P2.7. You can arm and disarm the counter and read or reset the counter through software. The USB-6501 supplies a nominal 5 V from two pins, one on each screw-terminal block. You can use the voltage source, which is provided by the USB host, to power external components. The USB-6501 features current-limiting short-circuit protection for safe USB host power use. Figure 1. Example of Connecting a Load Software The USB-6501 is shipped with NI-DAQmx measurement services software, a high-performance multithreaded driver for interactive configuration and data acquisition. Use it to develop customized data acquisition applications with NI LabVIEW or C-based development environments. Examples include an interactive control panel to help you get started with your application quickly. Figure 2. Interactive Control Panel Example Program Shipped with the USB-6501 Recommended Accessories The USB-6501 has built-in screw terminals for connectivity; no additional accessories are required. Board-Only Version for OEMs 2/8 www.ni.com
A board-only version of the USB-6501 (part number 192317-50) is available to OEMs for use in embedded applications. The OEM version offers a 34-pin IDC ribbon cable header for mass termination instead of screw-terminal connectivity. You can mount the OEM version using standoffs (not included in kit) with your own enclosure. For information on special configurations and pricing, visit ni.com/oem . Ordering Information For a complete list of accessories, visit the product page on ni.com. Products NI USB-6501 NI USB-6501 Part Number Recommended Accessories Part Number 779205-01 No accessories required. Back to Top Back to Top Software Recommendations LabVIEW Professional Development System for Windows NI LabWindows™/CVI for Windows Advanced software tools for large project development Automatic code generation using DAQ Assistant and Instrument I/O Assistant Tight integration with a wide range of hardware Advanced measurement analysis and digital signal processing Open connectivity with DLLs, ActiveX, and .NET objects Capability to build DLLs, executables, and MSI installers Real-time advanced 2D graphs and charts Complete hardware compatibility with IVI, VISA, DAQ, GPIB, and serial Analysis tools for array manipulation, signal processing statistics, and curve fitting Simplified cross-platform communication with network variables Measurement Studio .NET tools (included in LabWindows/CVI Full only) The mark LabWindows is used under a license from Microsoft Corporation. Back to Top Support and Services System Assurance Programs NI system assurance programs are designed to make it even easier for you to own an NI system. These programs include configuration and deployment services for your NI PXI, CompactRIO, or Compact FieldPoint system. The NI Basic System Assurance Program provides a simple integration test and ensures that your system is delivered completely assembled in one box. When you configure your system with the NI Standard System Assurance Program, you can select from available NI system driver sets and application development environments to create customized, reorderable software configurations. Your system arrives fully assembled and tested in one box with your software preinstalled. When you order your system with the standard program, you also receive system-specific documentation including a bill of materials, an integration test report, a recommended maintenance plan, and frequently asked question documents. Finally, the standard program reduces the total cost of owning an NI system by providing three years of warranty coverage and calibration service. Use the online product advisors at ni.com/advisor to find a system assurance program to meet your needs. Calibration NI measurement hardware is calibrated to ensure measurement accuracy and verify that the device meets its published specifications. To ensure the ongoing accuracy of your measurement hardware, NI offers basic or detailed recalibration service that provides ongoing ISO 9001 audit compliance and confidence in your measurements. To learn more about NI calibration services or to locate a qualified service center near you, contact your local sales office or visit ni.com/calibration. Technical Support Get answers to your technical questions using the following National Instruments resources. Support - Visit ni.com/support to access the NI KnowledgeBase, example programs, and tutorials or to contact our applications engineers who are located in NI sales offices around the world and speak the local language. Discussion Forums - Visit forums.ni.com for a diverse set of discussion boards on topics you care about. Online Community - Visit community.ni.com to find, contribute, or collaborate on customer-contributed technical content with users like you. Repair While you may never need your hardware repaired, NI understands that unexpected events may lead to necessary repairs. NI offers repair services performed by highly trained technicians who quickly return your device with the guarantee that it will perform to factory specifications. For more information, visit ni.com/repair. Training and Certifications The NI training and certification program delivers the fastest, most certain route to increased proficiency and productivity using NI software and hardware. Training builds the skills to more efficiently develop robust, maintainable applications, while certification validates your knowledge and ability. Classroom training in cities worldwide - the most comprehensive hands-on training taught by engineers. On-site training at your facility - an excellent option to train multiple employees at the same time. 3/8 www.ni.com
On-site training at your facility - an excellent option to train multiple employees at the same time. Online instructor-led training - lower-cost, remote training if classroom or on-site courses are not possible. Course kits - lowest-cost, self-paced training that you can use as reference guides. Training memberships and training credits - to buy now and schedule training later. Visit ni.com/training for more information. Extended Warranty NI offers options for extending the standard product warranty to meet the life-cycle requirements of your project. In addition, because NI understands that your requirements may change, the extended warranty is flexible in length and easily renewed. For more information, visit ni.com/warranty. OEM NI offers design-in consulting and product integration assistance if you need NI products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. Alliance Our Professional Services Team is comprised of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 700 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. Back to Top Detailed Specifications The following specifications are typical at 25 °C, unless otherwise noted. All voltages are relative to COM unless otherwise noted. Digital I/O Number of lines P0.<0..7> P1.<0..7> P2.<0..7> Direction control Output driver type Pull-up resistor Absolute voltage range Power-on state Digital Logic Levels Input low voltage Input high voltage Input leakage current Output low voltage Open collector (open-drain) or active drive (push-pull) I I OL OL = 2 mA = 8.5 mA Output high voltage Active drive (push-pull 1 ) I I OH OH = –2 mA = –8.5 mA Open collector (open-drain), I Open collector (open-drain), I OH OH = –0.4 mA, nominal = –7.5 mA, with external pull-up resistor Counter Number of counters 8 8 8 Input or output, software-selectable Active drive (push-pull) or open collector (open-drain), software selectable 4.7 kΩ VBus (nominally 5 V) – 0.5 to 5.8 V with respect to GND Input (high impedance) –0.3 V min, 0.8 V max 2.0 V min, 5.8 V max 50.0 μA max 0.4 V max 0.8 V max 2.8 V min, 3.6 V max 2.0 V min, 3.5 V max 2.0 V min, 5.0 V max 2.0 V min 1 (P2.7 can be configured as a counter) 4/8 www.ni.com
Resolution Counter measurements Maximum input frequency Minimum high pulse width Minimum low pulse width Bus Interface USB specification External Voltage +5 V output Voltage Current Power Requirements USB Input voltage Active current Suspend current Physical Characteristics Dimensions Without connectors With connectors I/O connectors Screw-terminal wiring Torque for screw terminals Weight Safety If you need to clean the module, wipe it with a dry towel. Overvoltage Protection Connect only voltages that are within these limits. Channel-to-COM (one channel) Channels-to-COM (one port, all channels) 32 bits Falling edge counting 5 MHz 100 ns 100 ns USB 2.0 Full-Speed (12 Mb/s) 4.00 V min, 5.25 V max 230 mA max 4.50 to 5.25 VDC, in configured state 80 mA typical, 500 mA max 500 μA max, all DIO lines disconnected 6.35 cm × 8.51 cm × 2.31 cm (2.50 in. × 3.35 in. × 0.91 in.) 8.18 cm × 8.51 cm × 2.31 cm (3.22 in. × 3.35 in. × 0.91 in.) USB series B receptacle, (2) 16 position (screw terminal) plug headers 16 to 28 AWG copper conductor wire with 10 mm (0.39 in.) of insulation stripped from the end 0.22 – 0.25 N · m (2.0 – 2.2 lb · in.) 84 g (3 oz) ±30 V max, Measurement Category I ±8.9 V max, Measurement Category I Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. voltage. This category is for 2 Caution Do not use this module for connection to signals or for measurements within Measurement Categories II, III, or IV. Safety Standards This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. Hazardous Locations This device is not certified for use in hazardous locations. Environmental The NI USB-6501 device is intended for indoor use only. Operating temperature (IEC 60068-2-1 and IEC 60068-2-2) Operating humidity (IEC 60068-2-56) Maximum altitude 0 to 55 °C 5 to 95% RH, noncondensing 2,000 m (at 25 °C ambient temperature) 5/8 www.ni.com
Storage temperature (IEC 60068-2-1 and IEC 60068-2-2) Storage humidity (IEC 60068-2-56) Pollution Degree (IEC 60664) Electromagnetic Compatibility – 40 to 85 °C 5 to 90% RH, noncondensing 2 This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement, control, and laboratory use: EN 61326 EMC requirements; Minimum Immunity EN 55011 Emissions; Group 1, Class A CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A Note For EMC compliance, operate this device with double-shielded cables. CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: 2006/95/EC; Low-Voltage Directive (safety) 2004/108/EC; Electromagnetic Compatibility Directive (EMC) Note For the standards applied to assess the EMC of this product, refer to the Online Product Certification section. Online Product Certification Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit ni.com/certification , search by module number or product line, and click the appropriate link in the Certification column. Environmental Management National Instruments is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial not only to the environment but also to NI customers. For additional environmental information, refer to the with which NI complies, as well as other environmental information not included in this document. NI and the Environment Web page at ni.com/environment . This page contains the environmental regulations and directives Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of their life cycle, all products Instruments WEEE initiatives, visit ni.com/environment/weee.htm . must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National 1 The total current sourced by all DO lines simultaneously should not exceed 65 mA. 2 MAINS is defined as the (hazardous live) electrical supply system to which equipment is designed to be connected for the purpose of powering the equipment. Suitably rated measuring circuits may be connected to the MAINS for measuring purposes. Back to Top 6/8 www.ni.com
Pinouts/Front Panel Connections NI USB-6501 Digital Terminal Assignments, Left 7/8 www.ni.com
NI USB-6501 Digital Terminal Assignments, Right Back to Top ©2010 National Instruments. All rights reserved. CompactRIO, CVI, FieldPoint, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com, NI-DAQ, and SignalExpress are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency, partnership, or joint-venture relationship with National Instruments. My Profile RSS Privacy Legal Contact NI © 2014 National Instruments Corporation. All rights reserved. | | | | 8/8 www.ni.com
分享到:
收藏