Overview
Features of SYSMAC OPC Server V2
System Requirements
Connection Target
Setup
Uninstalling old version of SYSMAC OPC Server and FinsGateway
Installing
Uninstalling
File Configuration
Basic Operations
Starting
Window Contents
Configuration of Toolbar
Configuration of Popup Menu
File Menu
Edit Menu
Add Menu
Separate sheet 1. Data type to be set to the area and its address range
Separate sheet 2. ASCII conversion specification
Separate sheet 3. Simulation type
Separate sheet 4. Scaling specification
View Menu
Tool Menu
FINS Communications
Device Connection Monitoring
Help Menu
Write Tag
Starting and Setting of Network
Setting of Network
Tag Convert Function
Tag Import Function
Import from CSV file(Device,Tag)
Import of CX-Process version1 Monitor Tag File
Import of CX-Process version2 or later CSV Tag File
Import of CX-Programmer V1.x Project
Import of CX-Programmer version2 or later Project
Tag Export Function
Export to CSV File(Device,Tag)
Export to CSV file for RSView32
Using from OPC Client
Using from OPC Sample Client (Local Connection)
Using from OPC Sample Client (Remote Connection)
Using from RSView32 V6.3
Registration of SYSMAC OPC Server V2 to RSView32
Registration of a Tag to RSView32
Appendix 1Response Performance (Reference Value)
Appendix 2OPC Implementation Interface
1. OPC Automation Interface
2. OPC Custom Interface
SYSMAC OPC Server V2.6 Operation Manual Programmable Controller SYSMAC SYSMAC OPC Server V2 Operation Manual V2.6 (1/95)
SYSMAC OPC Server V2.6 Operation Manual Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property. DANGER WARNING Caution Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage. (2/95)
SYSMAC OPC Server V2.6 Operation Manual Safety Precautions Caution Confirm safety at the destination node before transferring a program to another node or changing contents of the I/O memory area. Doing either of these without confirming safety may result in injury. Applications Precautions Observe the following precautions when using the SYSMAC OPC Server V2. - Fail-safe measures must be taken by the customer to ensure safety in the event of incorrect, missing, or abnormal signals caused by broken signal lines, momentary power interruptions, or other causes. - Confirm that no adverse effect will occur in the system before attempting any of the following. Not doing so may result in an unexpected operation. - Changing the operation mode of the PLC. - Force-setting/force-resetting any bit in memory. - Changing the present value of any word or any set value in memory. - Be sure that all the mounting screws, terminal screws, and cable connector screws are tightened to the torque specified in the relevant manuals. Incorrect tightening torque may result in malfunction. - Check the user program for proper execution before actually running it on the Unit. Not checking the program may result in an unexpected operation. - The tag setting file for the SYSMAC OPC Server V2 may not be saved in the event of a system failure or power interruptions. Saving the file regularly is recommended. - Check whether scaling is performed and whether scaling setting is correct in each tag before scaling. (3/95)
SYSMAC OPC Server V2.6 Operation Manual TABLE OF CONTENTS 1. 2. 3. 3.3. 3.4. 3.5. 1.1. 1.2. 1.3. 2.1. 2.2. 2.3. 2.4. Overview............................................................................................................................................ 8 Features of SYSMAC OPC Server V2 ....................................................................................... 8 System Requirements................................................................................................................. 9 Connection Target .................................................................................................................... 10 Setup................................................................................................................................................ 13 Uninstalling old version of SYSMAC OPC Server and FinsGateway................................... 13 Installing ................................................................................................................................... 13 Uninstalling .............................................................................................................................. 23 File Configuration..................................................................................................................... 26 Basic Operations ............................................................................................................................ 27 Starting ..................................................................................................................................... 27 3.1. 3.2. Window Contents...................................................................................................................... 28 3.2.1. Configuration of Toolbar ......................................................................................................... 29 3.2.2. Configuration of Popup Menu ................................................................................................. 29 File Menu .................................................................................................................................. 31 Edit Menu.................................................................................................................................. 32 Add Menu.................................................................................................................................. 33 ...................................................................................................................................... 34 ....................................................................................................................................... 36 ........................................................................................................................................... 37 ........................................................................................................................ 40 ................................................................................................................................ 41 Separate sheet 1. Data type to be set to the area and its address range ........................................... 45 Separate sheet 2. ASCII conversion specification............................................................................... 46 Separate sheet 3. Simulation type....................................................................................................... 47 Separate sheet 4. Scaling specification............................................................................................... 48 View Menu ................................................................................................................................ 51 Tool Menu.................................................................................................................................. 51 3.7.1. FINS Communications............................................................................................................ 55 3.7.2. Device Connection Monitoring................................................................................................ 55 3.8. Help Menu................................................................................................................................. 56 3.9. Write Tag................................................................................................................................... 57 Starting and Setting of Network.................................................................................................... 57 Setting of Network.................................................................................................................... 59 Tag Convert Function..................................................................................................................... 62 Tag Import Function ................................................................................................................ 62 Import from CSV file(Device,Tag)........................................................................................... 62 Import of CX-Process version1 Monitor Tag File.................................................................... 65 Import of CX-Process version2 or later CSV Tag File ............................................................ 66 5.1.1. 5.1.2. 5.1.3. 3.6. 3.7. 4. 5. 4.1. 5.1. (4/95)
SYSMAC OPC Server V2.6 Operation Manual 5.2. 5.1.4. 5.1.5. Import of CX-Programmer V1.x Project .................................................................................. 68 Import of CX-Programmer version2 or later Project ............................................................... 70 Tag Export Function................................................................................................................. 72 5.2.1. Export to CSV File(Device,Tag).............................................................................................. 72 5.2.2. Export to CSV file for RSView32............................................................................................. 74 Using from OPC Client................................................................................................................... 76 Using from OPC Sample Client (Local Connection)............................................................... 77 Using from OPC Sample Client (Remote Connection)........................................................... 78 Using from RSView32 V6.3...................................................................................................... 82 6.3.1. Registration of SYSMAC OPC Server V2 to RSView32......................................................... 83 6.3.2. Registration of a Tag to RSView32......................................................................................... 84 Response Performance (Reference Value).................................................................. 89 6. 6.1. 6.2. 6.3. Appendix 1 Appendix 2 OPC Implementation Interface...................................................................................... 90 1. OPC Automation Interface................................................................................................................ 90 2. OPC Custom Interface....................................................................................................................... 91 (5/95)
SYSMAC OPC Server V2.6 Operation Manual Introduction Thank you for purchasing the SYSMAC OPC Server V2. The SYSMAC OPC Server V2 is a local/remote server that runs on WindowsNT/ 2000/XP, corresponding to OPC Data Access1.0a/2.0. This provides you with an environment to connect the OPC client to OMRON's Programmable Logic Controllers (described as PLC hereafter). This manual explains how to operate the SYSMAC OPC Server V2 in detail. SYSMAC, FINS, and CX-Programmer are trademarks of Omron Corporation. Microsoft, Windows, WindowsNT, Windows2000, WindowsXP and Visual C++ are trademarks of Microsoft Corporation. Other company names and product names are trademarks of each corresponding company. Intended Audience This manual is intended for the following personnel, who must also have knowledge of electrical systems (an electrical engineer or the equivalent). - Personnel in charge of installing FA systems. - Personnel in charge of designing FA systems. - Personnel in charge of managing FA systems and facilities. General Precautions - The user must operate the product according to the performance specifications described in the operation manuals. - Before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, petrochemical plants, and other systems, machines, and equipment that may have a serious influence on lives and property if used improperly, consult your OMRON representative. - Make sure that the ratings and performance characteristics of the product are sufficient for the systems, machines, and equipment, and be sure to provide the systems, machines, and equipment with double safety mechanisms. - This manual provides information for operating the SYSMAC OPC Server V2. Be sure to read this manual before attempting to use this product and keep this manual close at hand for reference during operation. (6/95)
SYSMAC OPC Server V2.6 Operation Manual Safety Precautions Caution Confirm safety at the destination node before transferring a program to another node or changing contents of the I/O memory area. Doing either of these without confirming safety may result in injury. Caution Scaling by OPC Server may result in reading and writing a value different from the case when scaling is not performed and cause unexpected malfunction or a notification error, which may lead to an accident. Check whether scaling is performed and whether scaling setting is correct in each tag before scaling. Applications Precautions Observe the following precautions when using the SYSMAC OPC Server V2. - Fail-safe measures must be taken by the customer to ensure safety in the event of incorrect, missing, or abnormal signals caused by broken signal lines, momentary power interruptions, or other causes. - Confirm that no adverse effect will occur in the system before attempting any of the following. Not doing so may result in an unexpected operation. - Changing the operation mode of the PLC. - Force-setting/force-resetting any bit in memory. - Changing the present value of any word or any set value in memory. - Be sure that all the mounting screws, terminal screws, and cable connector screws are tightened to the torque specified in the relevant manuals. Incorrect tightening torque may result in malfunction. - Check the user program for proper execution before actually running it on the Unit. Not checking the program may result in an unexpected operation. - The tag setting file for the SYSMAC OPC Server V2 may not be saved in the event of a system failure or power interruptions. Saving the file regularly is recommended. (7/95)
SYSMAC OPC Server V2.6 Operation Manual 1. Overview 1.1. Features of SYSMAC OPC Server V2 The SYSMAC OPC Server V2 is a local/remote server that runs on WindowsNT/2000/XP, corresponding to OPC Data Access1.0a/2.0. This provides you with an environment to connect the OPC client to OMRON's Programmable Logic Controllers (described as PLC hereafter). [Features] - Easily connected from various OPC client applications. Using an OLE Automation interface allows to easily connect from Visual Basic5.0 or later / Excel97 or later. - Supports multiple network connections (Host link, Controller Link, and Ethernet etc.). - Provides an Explorer-like interface to create, indicate, and monitor tag data. - Created tag data can be saved and read as a tag setting file (*.sdb). - The IO simulation mode allows to connect and test an OPC client application without connecting - - an actual device. Imports Symbols (tags) in the ladder program created by the programming tool for Omron’s PLC (CX-Programmer). Also, exports to a CSV-format file, which can be imported to the RSView32 tag database. Imports a tag setting file created by the software tool for the Omron’s Loop Control Unit (CX-Process). - For a WORD/DWORD-type tag, BCD conversion can be performed; and for a STRING-type tag, Shift-JIS (Japanese edition) and ASCII (English edition) conversion can be performed. - Directly accesses Omron’s Loop Control Board (LCB) and Loop Control Unit (LCU). OPC Client (Local) OPC Client (Remote) COM1 COM2 Omron’s PLC/LCB/LCU Custom i/f Automation i/f SYSMAC OPC Server Tag data(*.sdb) FinsGateway Event Memory (CIO/DM) Import Omron’s software tool CX-Programmer .CX-Process Export HMI software RS-View32 Controller Link/Ethernet etc. Omron’s PLC/LCB/LCU (8/95)