1 SCOPE
1.1 Scope.
1.2 Purpose.
1.3 Application.
2 APPLICABLE DOCUMENTS
2.1 General.
2.2 Government documents.
2.2.1 Specifications, standards, and handbooks.
2.2.2 Other government documents, drawings, and publications.
2.3 Non-Government publications.
2.4 Order of precedence.
3 DEFINITIONS
3.1 Definitions.
3.1.1 Aircraft.
3.1.2 Aircraft/store Electrical Interconnection System (AEIS).
3.1.3 Electrical interface types.
3.1.3.1 Aircraft Station Interface (ASI).
3.1.3.2 Carriage Store Interface (CSI).
3.1.3.3 Carriage Store Station Interface (CSSI).
3.1.3.4 Mission Store Interface (MSI).
3.1.3.5 Routing Network Aircraft Subsystem Port (RNASP).
3.1.4 Provisions.
3.1.5 Store.
3.1.5.1 Carriage stores.
3.1.5.2 Mission stores.
3.1.5.3 Dispensers.
3.1.6 Stores management system.
3.1.7 Suspension and release equipment (S&RE).
3.1.8 Random noise.
3.1.9 Periodic noise.
3.1.10 Impulse noise.
3.1.11 Stimulated noise.
3.1.12 Common mode noise.
3.1.13 Latency.
3.1.14 Delay.
3.1.15 Power interruption.
3.1.16 Safety Critical. [Note 4]
3.1.17 DC Offset.
3.1.18 Fibre Channel.
3.2 Acronyms and abbreviations.
4 GENERAL REQUIREMENTS
4.1 Aircraft/store configurations.
4.2 Interface classes. [Note 3]
4.3 Primary interface signal set.
4.3.1 High bandwidth (HB) interfaces.
4.3.1.1 Type A signal requirements.
4.3.1.2 Type B signal requirements.
4.3.1.3 Signal assignment.
4.3.2 Data bus interfaces.
4.3.2.1 MIL-STD-1553 data bus interface. [Note 5]
4.3.2.2 Fibre Channel interface. [Note 3]
4.3.3 Low bandwidth (LB) interface.
4.3.3.1 LB signal requirements.
4.3.3.2 Signal assignment.
4.3.4 Release consent interface.
4.3.5 Primary interlock interface.
4.3.6 Address interface.
4.3.7 Primary structure ground.
4.3.8 Primary power.
4.3.9 Fiber optic (FO) interfaces.
4.4 Auxiliary power interface signal set.
4.4.1 Auxiliary power.
4.4.2 Auxiliary interlock interface.
4.4.3 Auxiliary structure ground.
4.5 Interface connectors.
5 DETAILED REQUIREMENTS
5.1 Aircraft requirements.
5.1.1 Aircraft HB interfaces.
5.1.1.1 Minimum transfer capacity.
5.1.1.2 Type A signal path requirements.
5.1.1.2.1 Return loss.
5.1.1.2.2 Transient response.
5.1.1.2.3 Insertion gain.
5.1.1.2.4 Representative pulse delay.
5.1.1.2.5 Equalization.
5.1.1.2.6 Dynamic range.
5.1.1.2.7 Signal path dc offset.
5.1.1.2.8 Noise requirements.
5.1.1.2.8.1 Random noise.
5.1.1.2.8.2 Periodic noise.
5.1.1.2.8.3 Impulse noise.
5.1.1.2.8.4 Stimulated noise.
5.1.1.2.8.5 Common mode noise.
5.1.1.3 Type B signal path requirements.
5.1.1.4 Ground reference.
5.1.2 Aircraft MIL-STD-1553 data bus interface.
5.1.2.1 Functional characteristics.
5.1.2.2 Electrical characteristics.
5.1.2.2.1 Output characteristics.
5.1.2.2.2 Input characteristics.
5.1.2.2.3 Shield grounding.
5.1.3 Aircraft LB interface.
5.1.3.1 Minimum transfer capacity.
5.1.3.2 Input/output impedance.
5.1.3.3 Insertion gain.
5.1.3.4 Equalization requirements.
5.1.3.5 Signal path dc offset.
5.1.3.6 Noise.
5.1.3.6.1 Periodic and random noise.
5.1.3.6.2 Impulse noise.
5.1.3.6.3 Stimulated noise.
5.1.3.6.4 Common mode noise.
5.1.3.7 Ground reference.
5.1.4 Aircraft release consent interface.
5.1.4.1 Voltage level.
5.1.4.2 Current level.
5.1.4.3 Stabilization time.
5.1.4.4 Enable lead time.
5.1.4.5 Inhibit delay.
5.1.4.6 Ground reference.
5.1.4.7 Duration of application to mission store. [Note 9]
5.1.5 Aircraft interlock interface.
5.1.6 Aircraft address interface.
5.1.6.1 Address assignment.
5.1.6.2 Address signal.
5.1.6.3 Logic thresholds.
5.1.6.4 Response characteristics.
5.1.6.5 Address isolation.
5.1.7 Aircraft structure ground.
5.1.8 Aircraft 28 V dc power interface.
5.1.8.1 Independent control.
5.1.8.2 Voltage level.
5.1.8.3 Current capacity.
5.1.8.3.1 Primary signal set.
5.1.8.3.2 Auxiliary power signal set.
5.1.8.3.3 Simultaneous current.
5.1.8.4 Overcurrent protection.
5.1.8.5 Off-state leakage current.
5.1.8.6 Stabilization time.
5.1.8.7 Ground reference.
5.1.8.8 Power application.
5.1.9 Aircraft 115/200 V 400 Hz ac power interface.
5.1.9.1 Independent control and dead facing.
5.1.9.2 Voltage level.
5.1.9.3 Current capacity.
5.1.9.3.1 Primary signal set.
5.1.9.3.2 Auxiliary power signal set.
5.1.9.3.3 Simultaneous current.
5.1.9.4 Overcurrent protection.
5.1.9.5 Off-state leakage current.
5.1.9.6 Stabilization time.
5.1.9.7 Phase rotation.
5.1.9.8 Load power factor.
5.1.9.9 Phase power unbalance.
5.1.9.10 Ground reference.
5.1.9.11 Power application.
5.1.10 Aircraft 270 V dc power interface.
5.1.10.1 Independent control and dead facing.
5.1.10.2 Voltage level.
5.1.10.3 Current capacity.
5.1.10.3.1 Primary signal set.
5.1.10.3.2 Auxiliary power signal set.
5.1.10.3.3 Simultaneous current.
5.1.10.4 Overcurrent protection.
5.1.10.5 Off-state leakage current.
5.1.10.6 Stabilization time.
5.1.10.7 Ground reference.
5.1.10.8 Power application.
5.1.11 Aircraft fiber optic interface.
5.1.12 Initialization.
5.1.12.1 Pre-initialization conditions.
5.1.12.2 Power application.
5.1.12.3 First communication.
5.1.13 Aircraft Fibre Channel Interface. [Note 3]
5.2 Mission store requirements (measured at the MSI).
5.2.1 Mission store HB interfaces.
5.2.1.1 Electrical characteristics (type A).
5.2.1.1.1 Return loss.
5.2.1.1.2 Dynamic range.
5.2.1.2 Electrical characteristics (type B).
5.2.1.3 Ground reference.
5.2.2 Mission store data bus interface.
5.2.2.1 Functional characteristics.
5.2.2.2 Electrical characteristics.
5.2.2.2.1 Output characteristics.
5.2.2.2.2 Input characteristics.
5.2.2.2.3 Shield grounding.
5.2.3 Mission store LB interface.
5.2.3.1 Input/output impedance.
5.2.3.2 Ground reference.
5.2.4 Mission store release consent interface.
5.2.4.1 Voltage level.
5.2.4.2 Current level.
5.2.4.3 Stabilization time.
5.2.4.4 Enable lead time.
5.2.4.5 Inhibit lead time.
5.2.4.6 Ground reference.
5.2.5 Mission store interlock interface.
5.2.6 Mission store address interface.
5.2.6.1 Address assignment.
5.2.6.2 Address signal.
5.2.6.3 Logic threshold.
5.2.6.4 Response characteristics.
5.2.7 Mission store structure ground.
5.2.8 Mission store 28 V dc power interface.
5.2.8.1 Voltage level.
5.2.8.2 Load current.
5.2.8.2.1 Primary signal set.
5.2.8.2.2 Auxiliary power signal set.
5.2.8.2.3 Simultaneous load.
5.2.8.3 Load isolation.
5.2.8.4 Overcurrent compatibility.
5.2.8.5 Off-state leakage current.
5.2.8.6 Stabilization time.
5.2.8.7 Ground reference.
5.2.8.8 Power utilization.
5.2.9 Mission store 115/200 V 400 Hz ac power interface.
5.2.9.1 Voltage level.
5.2.9.2 Load current.
5.2.9.2.1 Primary signal set.
5.2.9.2.2 Auxiliary power signal set.
5.2.9.2.3 Simultaneous load.
5.2.9.3 Load isolation.
5.2.9.4 Overcurrent compatibility.
5.2.9.5 Off-state leakage current.
5.2.9.6 Stabilization time.
5.2.9.7 Load power factor.
5.2.9.8 Phase utilization.
5.2.9.9 Ground reference.
5.2.9.10 Power utilization.
5.2.10 Mission store 270 V dc power interface.
5.2.10.1 Voltage level.
5.2.10.2 Load current.
5.2.10.2.1 Primary signal set.
5.2.10.2.2 Auxiliary power signal set.
5.2.10.2.3 Simultaneous load.
5.2.10.3 Load isolation.
5.2.10.4 Overcurrent compatibility.
5.2.10.5 Off-state leakage current.
5.2.10.6 Stabilization time.
5.2.10.7 Ground reference.
5.2.10.8 Power utilization.
5.2.11 Mission store fiber optic interface.
5.2.12 Store initialization.
5.2.12.1 Pre-initialization conditions.
5.2.12.2 Power application.
5.2.12.3 Address determination.
5.2.12.4 First response.
5.2.12.5 First required non-busy response.
5.2.12.6 First required full communication response.
5.2.13 Mission Store Fibre Channel Interface. [Note 3]
5.3 Carriage store requirements.
5.3.1 Carriage store HB interfaces.
5.3.1.1 Minimum transfer capacity.
5.3.1.2 Type A signal path characteristics.
5.3.1.2.1 Return loss.
5.3.1.2.2 Transient response.
5.3.1.2.3 Insertion gain.
5.3.1.2.4 Representative pulse delay.
5.3.1.2.5 Equalization.
5.3.1.2.6 Dynamic range.
5.3.1.2.7 Signal path dc offset.
5.3.1.2.8 Noise.
5.3.1.2.8.1 Random noise.
5.3.1.2.8.2 Periodic noise.
5.3.1.2.8.3 Impulse noise.
5.3.1.2.8.4 Stimulated noise.
5.3.1.2.8.5 Common mode noise.
5.3.1.3 Signal path electrical characteristics (type B).
5.3.1.4 Ground reference (type A).
5.3.1.5 Ground reference (type B).
5.3.2 Carriage store MIL-STD-1553 data bus interface.
5.3.2.1 CSI.
5.3.2.2 CSSI.
5.3.3 Carriage store LB interface.
5.3.3.1 Minimum transfer capacity.
5.3.3.2 Input/output impedance.
5.3.3.3 Insertion gain.
5.3.3.4 Equalization.
5.3.3.5 Signal path dc offset.
5.3.3.6 Noise.
5.3.3.6.1 Periodic and random noise.
5.3.3.6.2 Impulse noise.
5.3.3.6.3 Stimulated noise.
5.3.3.6.4 Common mode noise.
5.3.3.7 Ground reference.
5.3.4 Carriage store release consent interface.
5.3.4.1 CSI.
5.3.4.2 CSSI.
5.3.4.3 CSI to CSSI transfer.
5.3.5 Carriage store interlock interface.
5.3.5.1 CSI.
5.3.5.2 CSSI.
5.3.5.3 Isolation.
5.3.6 Carriage store address interface.
5.3.6.1 CSI.
5.3.6.2 CSSI.
5.3.7 Carriage store structure ground.
5.3.7.1 CSI structure ground characteristics.
5.3.7.2 CSSI structure ground characteristics.
5.3.8 Carriage store 28 V dc power interface.
5.3.8.1 CSI.
5.3.8.2 CSSI.
5.3.9 Carriage store 115/200 V ac power interfaces.
5.3.9.1 CSI.
5.3.9.2 CSSI.
5.3.10 Carriage store 270 V dc power interfaces.
5.3.10.1 CSI.
5.3.10.2 CSSI.
5.3.11 Carriage store fiber optic interface.
5.3.12 Carriage store initialization.
5.3.13 Carriage store fibre channel interface. [Note 3]
5.3.13.1 CSI.
5.3.13.2 CSSI.
5.4 Umbilical cable requirements.
5.4.1 Primary umbilical HB interfaces.
5.4.2 Primary umbilical data bus interface.
5.4.3 Primary umbilical LB interface.
5.4.4 Primary umbilical release consent interface.
5.4.5 Umbilical interlock interface.
5.4.6 Primary umbilical address interface.
5.4.7 Umbilical structure ground.
5.4.8 Umbilical 28 V dc power interface.
5.4.9 Umbilical 115 V ac power interface.
5.4.10 Umbilical 270 V dc power interface.
5.4.11 Primary umbilical fiber optic interface.
5.4.12 Umbilical gross shield.
5.4.13 Primary umbilical fibre channel interfaces.
5.5 Power interface interrupts.
5.5.1 Mission store compatibility.
5.5.2 Carriage store compatibility.
5.5.3 Aircraft compatibility.
5.5.3.1 Full initialization.
5.5.3.2 Partial initialization.
5.5.4 Store power interrupt notification.
5.6 Connector characteristics.
5.6.1 Primary interface connectors.
5.6.2 Auxiliary power interface connector.
5.6.3 Connector receptacle.
5.6.4 Plugged cavities.
5.6.5 Umbilical primary interface connectors.
5.6.6 Umbilical auxiliary interface connectors.
5.6.7 Connector keyway orientation.
5.6.7.1 ASI and CSSI.
5.6.7.2 MSI and CSI.
5.6.7.3 Umbilical cable.
5.6.8 Connector location.
5.6.8.1 ASI and CSSI.
5.6.8.2 MSI and CSI.
6 NOTES
6.1 Intended use.
6.1.1 Implementation.
6.2 Acquisition requirements.
6.3 International standardization agreement implementation.
6.4 Tailoring guidance.
6.5 Keyword listing.
6.6 Changes from previous issue.