logo资料库

XXX酒店综合布线方案.doc

第1页 / 共42页
第2页 / 共42页
第3页 / 共42页
第4页 / 共42页
第5页 / 共42页
第6页 / 共42页
第7页 / 共42页
第8页 / 共42页
资料共42页,剩余部分请下载后查看
目 录
信息点
信息插座(Information Outlet)
互补
EIA/TIA
超五类
配线间(箱)
配线架
工作站
配线架水平端
配线架垂直端
阻燃电缆
一.综合布线系统概述
1.1概述
1.2结构化综合布线系统的必要性
1.2.1现代通信发展的需要
1.2.2智能型办公大楼运转费用及经济效益的需要
1.2.3方便用户使用
1.2.4随着技术的发展,所需的集成费用降低
1.3PDS结构化综合布线系统的组成
1.3.1工作区子系统(WORK AREA):
1.3.2水平布线子系统(HORIZONTAL CABLING):
1.3.3主干线子系统(BACKBONE CABLING):
1.3.4管理子系统(TELECOMMUNICATIONS CLOSET):
1.3.5设备室子系统(EQUIPMENT ROMM):
1.3.6建筑群(ENTRANCE FACILITIES)子系统:
二.综合布线系统的特性
2.1兼容性
2.2开放性
2.3灵活性
2.4可靠性
2.5先进性
三.建筑结构评估
3.1确定设备间的位置
3.2干线系统的规模及其设计
3.3选择水平布线路由和方法
四.设计依据及方法
4.1设计依据
4.1.1标准
4.1.2安装与设计规范
4.2设计目标的确定
4.2.1设计目标的确定
4.2.2设计范围:
4.2.3设计原则
4.3系统设计等级
4.3.1基本型设计等级
4.3.2基本型设计等级具有如下特征:
4.3.3增强型设计等级
4.3.4增强型设计等级有如下特征:
4.3.5综合型设计等级
4.3.6综合设计等级的特征:
4.4综合结构化布线支持的数据应用:
4.5器件选择
4.6设计方法
5.1工作区系统
5.2水平布线子系统
5.3垂直干线子系统
5.4设备间子系统
五.各子系统的设计
6.1工作区子系统
6.1.1工作区子系统信息插座安装位置确定:
6.1.2工作区信息出口(IO)数量的确定及选型:
6.1.2.1.凯悦酒店信息点数量的确定:
6.1.2.2.XX酒店信息点产品型号的选型:
6.1.2.3.信息点统计
6.2水平布线子系统
6.2.1水平区的设计
6.2.2水平线缆路由设计:
6.3垂直干线子系统
6.3.1垂直干缆路由设计:
6.3.2垂直干线的选型与计算:
6.4管理子系统
6.4.1单点管理和双点管理
6.4.2主(分)配线间的设计
6.5总投资估算
六.综合布线系统测试手段方法和标准
7.1测试原因
7.2 测试模型
7.3双绞线系统的测试内容
7.4光缆系统的测试
七.技术服务
8.1布线系统管理文档
8.2完工测试
8.2.1线路测试
8.2.2联机测试
8.2.3测试标准
8.2.4测试人员:
8.3竣工文档
8.3.1线路测试报告
8.3.2布线系统管理文档。
8.3.3布线系统竣工平面图。
8.4施工责任与质量保证
8.4.1穿线前检查
8.4.2穿线检查
八.公司简介
九.服务与质保
十.配套设计要求
XX 酒店 综合布线系统方案建议书 目 录 目 录················································································································································ 1 定义与习惯用语································································································································ 3 一. 综合布线系统概述················································································································5 1.1 概述 ··································································································· 5 1.2 结构化综合布线系统的必要性 ··································································7 PDS 结构化综合布线系统的组成 ································································8 1.3 二. 综合布线系统的特性··········································································································12 2.1 兼容性 ·······························································································12 2.2 开放性 ·······························································································12 2.3 灵活性 ·······························································································13 2.4 可靠性 ·······························································································13 2.5 先进性 ·······························································································13 三. 建筑结构评估······················································································································ 14 3.1 确定设备间的位置 ················································································14 3.2 干线系统的规模及其设计 ······································································ 14 3.3 选择水平布线路由和方法 ······································································ 15 四. 设计依据及方法··················································································································15 4.1 设计依据 ····························································································15 4.2 设计目标的确定 ···················································································16 4.3 系统设计等级 ······················································································17 4.4 综合结构化布线支持的数据应用: ·························································· 18 4.5 器件选择 ····························································································18 4.6 设计方法 ····························································································19 ——————————————————————————————
5.1 工作区系统 ·························································································20 5.2 水平布线子系统 ···················································································20 5.3 垂直干线子系统 ···················································································21 5.4 设备间子系统 ······················································································21 五. 各子系统的设计··················································································································21 6.1 工作区子系统 ······················································································21 6.2 水平布线子系统 ···················································································24 6.3 垂直干线子系统 ···················································································26 6.4 管理子系统 ·························································································27 6.5 总投资估算 ·························································································30 六. 综合布线系统测试手段方法和标准··················································································31 7.1 测试原因 ····························································································31 7.2 测试模型 ····························································································31 7.3 双绞线系统的测试内容 ········································································· 32 7.4 光缆系统的测试 ···················································································38 七. 技术服务······························································································································ 38 8.1 布线系统管理文档 ················································································38 8.2 完工测试 ····························································································39 8.3 竣工文档 ····························································································40 8.4 施工责任与质量保证 ·············································································40 八. 公司简介······························································································································ 40 九. 服务与质保·························································································································· 41 十. 配套设计要求······················································································································ 41 ——————————————————————————————
定义与习惯用语 信息点 指布线系统中的一个设备连接点,与信息插座的一个插孔对应。较常见的信 息设备是电话和计算机。 信息插座(Information Outlet) 布线系统中水平子系统的一部分,与工作区子系统相连。信息插座由面板和 插孔模块等组成,面板分暗嵌式和外露式,插孔数也有多种。插座不与信息点一 一对应,往往一个插座中既有计算机插孔又有电话插孔。 互补 电话和计算机插座的互补是指可以把计算机插孔改接电话,或把电话插孔改接 计算机。互补对综合布线系统的设计有一定要求。 EIA/TIA Electronic Industries Association/Telecommunication Industries Association(电子工业协会/通讯工业协会)的缩写。EIA/TIA568 是目前被业界广 泛遵循的布线标准。 超五类 是 EIA/TIA 公告 TSB-36 和 TSB-40 中规定的支持 150MBPS 以下传输率的布线 系统器件类别。如果要支持 150MBPS 的传输,要求这个布线系统的所有的器件, 包括电缆和插接件,都必须是五类产品。 配线间(箱) 属布线系统的管理子系统,其中放置配线架。典型的,设备间(本设计中就是 ——————————————————————————————
主机房)中放置主配线箱;每层楼设一个卫星配线箱,卫星配线箱设置的多少随各 楼层的信息点密度不同而不同。 配线架 配线间(管理子系统)中多种配线器件的总称。像配线间(箱)一样,也分为主配 线架和卫星配线架;主配线架连接主干电缆和设备,卫星配线架连接水平电缆和 主干电缆。 工作站 计算机网络中普通用户使用的计算机,与服务器相对,可以共享服务器上的 资源。 配线架水平端 一般地,我们把配线架与水平电缆相连的部分称作水平端。 配线架垂直端 一般地,我们把配线架与垂直主干相连的部分称作垂直端。 阻燃电缆 指电缆点燃后在限定的时间内,火焰沿电缆蔓延到限定的距离内可以自动熄 灭。 ——————————————————————————————
一. 综合布线系统概述 1.1 概述 随着社会的发展,现代办公建筑往往需要敷设各种电缆,如电话线、数据线、 电视线路、空调、灯光、火警、保安等;还有某些为满足特定需要而铺设的线路。 每一条线路都是为一特定的用途而设计安装的。如果采用传统的方法,每一条线 路的设计和安装都与其它线路不相干,而且各线路的线缆型号和规格也不相同, 结果造成办公楼的管理者面对的是一些互不相关的线缆系统所组成的毫无组织的 布线环境。 从历史上看,这种非结构化布线系统是由于分工和责任分担造成的。例如: 一 个人负责话音(电话),而另一个人负责数据(计算机),各有各的需求和预算。线缆 系统的供应商们同样也分为话音和数据两类,每一方都不知道也不关心另一方在 做什么,再加上各式各样的楼宇控制及管理系统,情况就变得更加复杂。这就是 过去大楼总是被线缆堵塞,而其中有大部分实际上已经废弃的原因。因此旧大楼 要花大笔钱用于合并、转移、改动、重新安装电缆。 试想,如果在大楼或园区内有一个综合的布线系统,联接通讯、数据处理及传 统的楼宇控制系统,那对使用者的益处是显而易见的,包括:减少人力物力的花费、 一次性安装、系统集成只需一个连接点、需要的实际空间较小、降低重新布置(移 动或改变)及维护管理的费用,而且能够更轻松地采用新的技术,降低风险和费用。 结构化综合布线系统(Premises Distribution System--PDS)就是这样一个系 统。 建筑物综合布线系统(Building Premises Distribution System)又称开放式 布线系统(Open Cabling System)是一种在建筑物和建筑群中综合数据的网络系 统。它是把建筑物内部的语音交换、智能数据处理设备及其它广义的数据通信设 施相互连接起来,并采用必要的设备同建筑物外部数据网络或电信局线路相连接, 其系统包括所有建筑与建筑群内部用以交连以上设备的电缆和相关的布线器件。 综合布线系统是 1985 年内美国电报电话公司公司贝尔实验室首先推出,并于 1986 年通过美国电子工业协会(EIA)和通信工业协会(TIA)的认证。于是很快得到 世界广泛认同,并在全球范围内推广。PDS 出现的意义,在于它彻底打破了数据传 ——————————————————————————————
输和语音传输的界限,并使这两种不同的信号在一条线路中传输,从而为综合业 务数据网络(ISDN)的实施提供了传输保证。 建筑物或建筑群内办公自动化设备都是因用户的应用需要而设置的。在传统 上,具体应用都以各自满足不同应用的需求而设计、安装,其结果就是难以对整 幢大楼的所有线路进行有效的管理;更有甚者,对将来网络改造造成很大的困难。 如果有一个结构化综合布线系统可以把整个大楼的所有线路集成在一个布线系统 中,统一设计、统一安装,这样不但减少了安装空间、改动费用、维修和管理费 用,而且能较轻易地以较便宜的成本及可靠的技术接驳最新型的系统。 结构化综合布线系统是建筑物内的信息传输网络。结构化综合布线系统由不 同系列的部件组成,其中包括:传输介质,线路管理硬件、连接器、插座、插头、 适配器和支持硬件。上述这些部件被用来构建各种子系统,它们都有各自的具体 功能与作用。不仅易于实施,而且能随需求的改变而平稳过渡增强型分布技术。 结构化综合布线系统的设计,要求系统设计师在对拟议的布线系统解决完之 前,安全而彻底地评估用户的需求。以便该结构化布线系统的设计更加合理、可 靠。 大家都知道,要实现智能化办公大楼,计算机网络和结构化综合布线系统是 智能化大厦基础设施的重要组成部分,而结构化综合布线系统在上述基础设施中 的重要性方面较计算机网络更为重要。 PDS 是一套综合的布线系统。PDS 是针对计算机与通信的配线系统而设计的, 这也就表明它可以满足各种不同的计算机与通信的要求。包括: 1) 模拟与数字的语音系统 2) 高速与低速的数据系统 3) 传真机、图形终端、绘图仪等需要传输的图像资料 4) 电话会议与安全监控系统的视频信号 5) 传输 28 个 VHF 宽带视频信号 6) 建筑物的安全报警和空调控制系统的传感器信号 PDS 可满足建筑物内部及建筑物之间的所有计算机、通信以及建筑物自动化系 统设备的配线要求。由于 PDS 是一套综合式的系统,因此它可以使用相同的电缆 与配线端子板,以及相同的插头与模块化插孔以供语音与数据的传递,可不考虑 各种设备的兼容性问题。 ——————————————————————————————
1.2 结构化综合布线系统的必要性 1.2.1 现代通信发展的需要 通讯技术是现代经济发展的媒介,而智能型大厦(楼)技术的核心正是通信技 术。现代通信工业的发展具有这样几种趋势:计算机和通信工业朝世界性的标准 化和通信设施的个人化方向发展;计算机和通信工业朝系统集成的方向发展。综合 业务数字网(ISDN)的发展,表明要把尽可能多的通信、计算机功能集成到一个单 一的系统中;要把所有的业务,包括话音、数据和图像都转换成数字的形式进行统 一处理;光纤技术引入局部通讯网(包括局部用户回路和办公室大厦等),如光纤数 据分布接口(FDDI)。 智能型办公大楼的核心是通信技术。 智能大厦系统正是为了适应现代通信技术的发展而产生的。现代通信技术的 发展非常迅速,这就要求我们以强有力的通讯系统作为大厦智能化的核心,并利 用大厦配线系统提供的灵活性、模块性、开放性,来满足用户目前和将来的需要。 1.2.2 智能型办公大楼运转费用及经济效益的需要 在传统大厦设计的相当早期阶段,就应该有房地产开发商、用户和通信设计 人员共同参加,并要提前一段时间先设计方案,选择设备供应商,还要给设备供 应商一段时间,才能完成设备的选购;同时要想在短时间内,解决因各种技术方 案和用户需求在客观上必然会有的不确定性和易于变化所带来的复杂问题,是非 常困难的。 然而,PDS 布线系统可以提供一个工程性能良好的平台。利用这个平台可以提 供任何类型的大厦业务,使这个建筑项目有很大的灵活性和通用性,同时, 又是以 非常迅速和好的性能价格比的方式实现。 1.2.3 方便用户使用 智能大厦(楼)系统可以给建筑者和管理者提供一种功能, 使得当工作人员因 位置变动、业务变更(增加、移动等)时候,需要支付的大规模修建费用保持在最 低。末端用户的业务请求,如电话、微机等设备的重要布局或增加额外的办公室 功能等,都易于在建筑期间或大楼的生命周期内完成,不必重新设计网络或使用 附加配线,就能保证对用户的需求做出最快的反应。而在传统大厦里,这类反应 通常需要几个星期。 ——————————————————————————————
1.2.4 随着技术的发展,所需的集成费用降低 PDS 布线系统可以把所有不同类型的电话系统(包括 ISDN)和由有关单位提供 的能源、保安、火灾安全等系统都集成在一起。因此随着技术发展所需的集成问 题以及与此相关的费用都可以保持在尽可能低的程度。 1.3 PDS 结构化综合布线系统的组成 PDS 采用模块化设计,因而最易于配线上扩充和重新组合,此系统采用星形拓 扑结构,并同电信方面以及 EIA/TIA568 所遵循的建筑物配线方式相同。 由于它采用了星形拓扑结构的模块化设计,才使扩充系统工作变得十分方便。 因为在星形拓扑结构中,工作站是由中心节点向外增设,而每条线路都与其它线 路无关,因此,在更改和重新布置设备时,只是影响到与此相关的那条线路,而 对其它所有线路毫无影响。另外,这种结构会使系统中的故障分离工作变得非常 容易。一旦系统发生故障,便可迅速地找到故障点,并加以排除。 PDS 布线系统包括布置在楼群中的所有线缆以及各种配件,如转接设备、各 类用户端口以及与外界网络的接口(如电话局)等(但不包括各种交换设备)。PDS 布 线系统的地位如下图所示: 计算机设备 计算机设备 外部通信环境 外部通信环境 网络接口 网络接口 综合布线系统 综合布线系统 通信设备 通信设备 通信管理系统 通信管理系统 综合结构化布线系统是智能大厦必不可少的部分,它由六个子系统组成,采 用星形结构,并使任何一个子系统独立地进入 PDS 系统中。它们是: 1.3.1 工作区子系统(WORK AREA): 工作区子系统由终端设备连接到信息插座的连线组成,它包括连接器和适配 器。由终端设备和连接到信息插座的连线组成,包括信息插座、插座盒(或面板)、 装配软线,适配器和连接所需的扩展软线,并在终端设备和 I/O 之间搭桥。 ——————————————————————————————
分享到: