SIMIT UNIT V1.3
Legal information - Warning notice system
Table of contents
1 Introduction
1.1 Introduction SIMIT UNIT
1.2 SIMIT UNIT product group
1.3 Type designation
2 Safety instructions
2.1 Important notes on using devices of the SIMIT UNIT product family
2.2 Important notes on using the device in hazardous areas
3 Description
3.1 Unpacking and checking
3.2 Scope of delivery
3.3 SIMIT UNIT product group
3.3.1 SIMIT UNIT PN
3.3.2 SIMIT UNIT PB
3.4 Ethernet network connectors P1 and P2 as well as N1 and N2
3.5 Control port
3.6 USB host
3.7 PROFIBUS port
3.8 Micro SD card
3.8.1 Position of the Micro SD memory card
3.9 Digital I/O for SIMIT UNIT PN
3.10 Digital I/O for SIMIT UNIT PB
3.11 Description of the LEDs
3.12 The button
4 Installing
4.1 Installation instructions
4.2 Installation options
4.3 General installation
4.3.1 Standard rail mounting
4.3.2 Installation on a standard rail
4.3.3 Wall mounting
5 Wiring
5.1 General information on commissioning
5.2 General power supply
5.3 Power supply
5.3.1 Connecting the power supply
5.3.2 24 V DC – SIMIT UNIT
5.4 Connecting digital inputs/outputs
5.5 Connecting the functional grounding
6 Technical specifications
6.1 Construction, installation and ambient conditions
6.2 Connectors and electrical data
6.3 Cable lengths
6.4 Additional properties
7 Dimension drawings
7.1 SIMIT UNIT PN
7.2 SIMIT UNIT PB
8 Approvals
8.1 Approvals, certificates SIMIT UNIT
8.2 Declaration of conformity SIMIT UNIT
8.3 Overview of the approvals SIMIT UNIT
8.4 SIMIT UNIT mechanical stability (in operation)
SIMATIC SIMIT UNIT V1.3 Operating Instructions Introduction Safety instructions Description Installing Wiring Technical specifications Dimension drawings Approvals 1 2 3 4 5 6 7 8
Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Trademarks All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY Ⓟ 07/2017 Subject to change Copyright © Siemens AG . All rights reserved
Table of contents 1 2 3 4 5 Introduction...................................................................................................................................................5 1.1 Introduction SIMIT UNIT..........................................................................................................5 SIMIT UNIT product group.......................................................................................................5 1.2 1.3 Type designation......................................................................................................................6 Safety instructions........................................................................................................................................7 Important notes on using devices of the SIMIT UNIT product family.......................................7 2.1 2.2 Important notes on using the device in hazardous areas.........................................................9 Description..................................................................................................................................................11 Unpacking and checking........................................................................................................11 3.1 3.2 Scope of delivery....................................................................................................................11 SIMIT UNIT product group.....................................................................................................11 3.3 SIMIT UNIT PN......................................................................................................................11 3.3.1 SIMIT UNIT PB......................................................................................................................12 3.3.2 3.4 Ethernet network connectors P1 and P2 as well as N1 and N2.............................................12 Control port............................................................................................................................13 3.5 3.6 USB host................................................................................................................................13 PROFIBUS port......................................................................................................................13 3.7 Micro SD card........................................................................................................................13 3.8 Position of the Micro SD memory card...................................................................................14 3.8.1 3.9 Digital I/O for SIMIT UNIT PN................................................................................................14 Digital I/O for SIMIT UNIT PB................................................................................................15 3.10 3.11 Description of the LEDs.........................................................................................................15 3.12 The button..............................................................................................................................16 Installing.....................................................................................................................................................17 4.1 Installation instructions...........................................................................................................17 Installation options.................................................................................................................18 4.2 General installation................................................................................................................18 4.3 Standard rail mounting...........................................................................................................18 4.3.1 4.3.2 Installation on a standard rail.................................................................................................19 4.3.3 Wall mounting........................................................................................................................20 Wiring.........................................................................................................................................................21 5.1 General information on commissioning..................................................................................21 General power supply............................................................................................................21 5.2 SIMIT UNIT V1.3 Operating Instructions 3
Table of contents Power supply..........................................................................................................................21 5.3 Connecting the power supply.................................................................................................21 5.3.1 24 V DC – SIMIT UNIT...........................................................................................................22 5.3.2 Connecting digital inputs/outputs...........................................................................................22 5.4 5.5 Connecting the functional grounding......................................................................................23 Technical specifications..............................................................................................................................25 Construction, installation and ambient conditions..................................................................25 6.1 Connectors and electrical data...............................................................................................26 6.2 6.3 Cable lengths.........................................................................................................................27 6.4 Additional properties..............................................................................................................28 Dimension drawings...................................................................................................................................29 7.1 SIMIT UNIT PN......................................................................................................................29 7.2 SIMIT UNIT PB......................................................................................................................30 Approvals....................................................................................................................................................31 Approvals, certificates SIMIT UNIT........................................................................................31 8.1 Declaration of conformity SIMIT UNIT...................................................................................32 8.2 8.3 Overview of the approvals SIMIT UNIT..................................................................................32 SIMIT UNIT mechanical stability (in operation)......................................................................33 8.4 SIMIT UNIT V1.3 Operating Instructions 6 7 8 4
Introduction 1.1 Introduction SIMIT UNIT 1 Purpose of the Operating Instructions (compact) These operating instructions (compact) contain information with which you will be able to install and connect up a device of the SIMIT UNIT product line. Validity of these Operating Instructions (compact) These operating instructions (compact) cover the SIMULATION (Hardware in the Loop) product line within the SIMIT product group (see Product overview). Table 1-1 Classification Product line Product group Device Variant All variants of a device Names of the devices in these operating instructions (compact) Description For all devices and variants of all product groups within the SIMIT product line, the term SIMULATION is used. For all devices and variants of a product group, only the product group is used. For a device, only the device name is used. For a variant of the device, the device name has the ap‐ propriate variant added to it in brackets (PN for PROFI‐ NET, PB for PROFIBUS). For all variants of the device, the device name has (all) added to it. Terms used SIMULATION (Hard‐ ware in the Loop) SIMIT SIMIT UNIT (-) (-) Where can I find detailed information on the product? You can find additional information here: ● Internet (https://support.industry.siemens.com/cs/ww/de/view/109746192) ● SIMIT Information system 1.2 SIMIT UNIT product group Product line SIMULATION hardware SIMULATION hardware SIMULATION hardware Product group SIMIT UNIT Device SIMIT UNIT PN 128 (Variant) (Profinet 128) [Order number] 9AE4120-2AA00 SIMIT UNIT SIMIT UNIT PN 256 (Profinet 256) 9AE4120-2AB00 SIMIT UNIT SIMIT UNIT PB 2 (Profibus, dual chan‐ nel) 9AE4122-2AA00 SIMIT UNIT V1.3 Operating Instructions 5
Introduction 1.3 Type designation 1.3 Type designation Structure of the type designation The type designation of a SIMIT UNIT is made up of several parts that have the following meaning: Product line SIMIT SIMIT SIMIT Product group SIMIT UNIT SIMIT UNIT SIMIT UNIT Device (variant) SIMIT UNIT PN 128 (Profinet 128) SIMIT UNIT PN 256 (Profinet 256) SIMIT UNIT PB 2 (Profibus, dual channel) [Order number] 9AE4120-2AA00 9AE4120-2AB00 9AE4122-2AA00 6 SIMIT UNIT V1.3 Operating Instructions
Safety instructions 2 2.1 Important notes on using devices of the SIMIT UNIT product family Safety notices on the use of the device The following safety notices must be adhered to when setting up and operating the device and during all work relating to it such as installation, connecting up, replacing devices or opening the device. General Information WARNING Safety extra-low voltage The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS). (This does not apply to 100 V...240 V devices.) This means that only Safety Extra-Low Voltages (SELV) with Limited Power Source (LPS) complying with IEC 60950-1 / EN 60950-1 / VDE 0805-1 must be connected to the power supply terminals. The power supply unit for the equipment power supply must comply with NEC Class 2, as described by the National Electrical Code ® (ANSI / NFPA 70). There is an additional requirement if devices are operated with a redundant power supply: If the device is connected to a redundant power supply (two separate power supplies), both must meet these requirements. WARNING Opening the device DO NOT OPEN THE DEVICE WHEN ENERGIZED. General notices regarding use in hazardous areas WARNING Risk of explosion when connecting or disconnecting the device DANGER OF EXPLOSION DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT. SIMIT UNIT V1.3 Operating Instructions 7
Safety instructions 2.1 Important notes on using devices of the SIMIT UNIT product family WARNING Replacing components DANGER OF EXPLOSION REPLACEMENT OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2 OR ZONE 2. WARNING Requirements for the control cabinet When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure. Notice for use in hazardous areas according to ATEX WARNING Requirements for the control cabinet To comply with EU Directive 94/9 (ATEX95), this enclosure must meet the requirements of at least IP54 in compliance with EN 60529. WARNING Suitable cables for temperatures in excess of 70 °C If the cable or conduit entry point exceeds 70 °C or the branching point of conductors exceeds 80 °C, special precautions must be taken. If the equipment is operated at ambient temperatures of 50 °C to 70 °C, only use cables with a permitted operating temperature of at least 80 °C. WARNING Protection against transient voltage surges Provisions shall be made to prevent the rated voltage from being exceeded by transient voltage surges of more than 40%. This criterion is fulfilled, if supplies are derived from SELV (Safety Extra-Low Voltage) only. 8 SIMIT UNIT V1.3 Operating Instructions
分享到:
收藏