MODEL UX-K01 s Handset les .4GHz Cord ANUAL N M 2 OPERATIO Charge the battery for about 10 hours before initial use. 1. Introduction 2. Connecting the Cordless Handset Charger 3. Installing and Charging the Battery 4. Registering the Cordless Handset 5. Enterring a Name for the Cordless Handset 6. Maintenance
I n t r o d u c t i o n Thank you for To use the UX-K01 purchasing a UX-K01 cordless handset, you cordless handset. must have a UX-CC500 fax machine. Specifications Frequency 2.4 GHz (2.405 to 2.475 GHz) Dimensions Width: 1.8" (46 mm) Depth: 1.7" (42 mm) Height: 7.1" (180 mm) (not including antenna) Weight Approx. 0.3 lbs. (115 g) (without battery) Battery 3.6 V Ni-MH battery; capacity: 850 mAh Power consumption Approx. 1.0 W (in standby mode) Initial charging Approx. 10 hours for initial charge Battery life Approx. 4 hours (240 minutes) (at room temp.) Battery life in standby Approx. 3 days with one full charge (at room mode temperature) Battery life (both normal and in standby mode) may vary depending on usage, range from base machine, and environmental conditions such as temperature. As a part of our policy of continuous improvement, SHARP reserves the right to make design and specification changes for product improvement without prior notice. The performance specification figures indicated are nominal values of production units. There may be some deviations from these values in individual units. 1
Important safety information Do not disassemble this product or attempt any procedures not described in this manual. Refer all servicing to qualified service personnel. Do not this product near water, or when you are wet. For example, do not use the product near a bath tub, wash bowl, kitchen sink or laundry tub, in a wet basement, or near a swimming pool. Take care not to spill any liquids on the product. Unplug the product from the power outlet and consult a qualified service representative if any of the following situations occur: - Liquid has been spilled into the product or the product has been exposed to rain or water. - The product produces odors, smoke, or unusual noises. - The power cord is frayed or damaged. - The product has been dropped or the housing damaged. Do not allow anything to rest on the power cord, and do not install the product where people may walk on the power cord. The AC adapter must only be connected to a 120 V, 60 Hz outlet. Connecting it to any other kind of outlet will damage the machine and invalidate the warranty. Never insert objects of any kind into slots or openings on the product. This could create a risk of fire or electric shock. If an object falls into the product that you cannot remove, unplug the product and consult a qualified service representative. Do not place this product on an unstable cart, stand or table. The product could be seriously damaged if it falls. Battery Use only the battery specified in this manual. Use only the provided charger to charge the battery. Do not open or mutilate the battery pack. Corrosive fluid may leak out and cause injury or burns to the eyes and skin. The fluid may be toxic if swallowed. In case of contact with eyes, flush with clean water (do not rub), and seek medical attention immediately. Do not store or carry the battery with other metal objects such as keys or pins. These may short the battery and cause it to overheat. Do not allow the battery to become wet. Do not dispose of the battery in a fire or heat the battery. The battery may explode. Health care facilities and equipment Radio frequency energy emitted from the cordless handset equipment may cause medical equipment to malfunction. Verify that any personal medical equipment you are using is adequately shielded from external radio frequency energy before using the cordless handset equipment. Do not use the cordless handset equipment in health care facilities where such use is prohibited. 2
Connecting the Cordless Handset Charger 1 Connect the AC adapter to the Fit the cord into cordless handset charger. the holders. 2 Plug the AC adapter into a standard 120 V AC outlet. Important: Never cover the charger and AC adapter with a blanket, cloth, or other material. Excessive heating may result and cause fire. Installing and Charging the Battery 1 Connect the battery connector ➊, and then place the battery pack in the cordless handset. Black Red Red Black 2 Place the battery cover on the cordless handset, making sure it snaps firmly into place. • Make sure the wires are not caught or pinched by the cover. 3
3 Place the cordless handset in the charger with the dial pad facing forward. • Important! The dial pad must face forward, or the battery will not charge. • The battery charges automatically while the cordless handset is in the charger. While charging, the display shows CHARGING. Charge the battery • When charging is completed the first at least 10 hours the first time! time, the display shows PLEASE REGISTER. After the handset is registered, the display shows IN CHARGER while in the charger. ♦ The cordless handset and charger may feel warm while charging. This is normal. ♦ The battery cannot be overcharged. When not using the cordless handset, keep it in the charger to ensure that it is always charged. When the battery needs charging, LOW BATTERY will appear in the display and you will hear beeps during a phone conversation. Place the cordless handset in the charger and let it charge. Note: If the battery is extremely low, nothing may appear in the display during the first several minutes that the cordless handset is in the charger. The battery will begin to charge normally after several minutes. Talking range The talking range of the cordless handset is approximately 1200 ft. (400 m) (line of sight). If you hear noise or interference while talking on the cordless handset, move closer to the fax machine. ♦ When outside the talking range, OUT OF RANGE appears in the display. If you move out of the talking range while talking on the cordless handset, the handset will beep and you may hear interference. Aluminum sash Metal Reinforced concrete Large metal objects, metal structures, and thick walls reduce the talking range. 4
Registering the Cordless Handset After the initial charging, To use the cordless the cordless handset display shows: handset, you must first register it using PLEASE REGISTER the fax machine. 1 Cordless handset display: On the cordless handset, hold down MODE SELECT INTER COM until the display at right appears. 1: HS ENTRY 2: HS DELETE 2 Press 1 on the cordless handset. HS ENTRY MODE • If FAX BUSY appears in the display, wait until the fax machine is no longer in use and then start from Step 1 again. Fax machine display: 3 On the fax machine, hold down INTERCOM MODE SELECT until the display at right appears. 1: HS ENTRY 2: HS DELETE 4 Press 1 on the fax machine. PRESS HS NUMBER • If HS FULL ENTRY appears in the display, the maximum number (3) of additional cordless handsets have already been registered. 5 On the fax machine, enter a number Example: “2” is selected from 2 to 4. This number identifies the HS2 ENTERED cordless handset. This completes the registration procedure. HS2 ENTERED • If ALREADY STORED appears in the display, the number you selected has already been assigned to a cordless handset. Try a different number. Both displays return to the normal standby display 5
The fax machine is identified by the number “0”, and the cordless handset that was included with the fax is identified by the number “1”. Entering a Name for the Cordless Handset Enter a name for the cordless handset in the fax machine. ♦ The fax machine will transmit the name that you enter to your cordless handset. 1 Fax machine display: Press FUNCTION once and 3 times on the fax machine. ENTRY MODE 2 Press once and once. HS NAME SET 3 Press once. 1=SET, 2=CLEAR 4 Press 1 to select SET. SELECT ID NO. 5 Enter the number of the cordless handset for which you wish to enter a Example: Cordless handset 2 name. SELECT ID NO. 2 Example: 2 6
6 Enter the name by pressing number keys for each letter as shown in the chart below. Up to 10 characters can be entered. Example: BILL = 22 444 555 555 SPACE = G = N = U = A = H = O = V = B = I = P = W = C = J = Q = X = D = K = R = Y = E = L = S = Z = F = M = T = ♦ To enter two letters in succession that require the same key, press after entering the first letter. ♦ SPEAKER To clear a mistake, press . ♦ To enter a lower case letter, continue pressing the key for the letter until the lower case letter appears. ♦ To enter one of the following symbols, press or repeatedly: . / ! " # $ % & ’ ( ) + + , - : ; < = > ? @ [ ¥ ] ^ _ ' { | } ) ( 7 START/MEMORY Display: Press to store the name. OWN NUMBER The handset number and name 8 STOP Press to exit. appear in the standby display: HANDSET2 BILL For information on The cordless operating the handset is now cordless handset, ready to be used! see your UX-CC500 manual. 7