Connecting a PC Station to an S7-1200 using OPC
1 Introduction
2 Procedure for S7-1200 up to firmware V3
2.1 Configuration of the S7-1200
2.1.1 Configuring the Hardware
2.1.2 Creating a User Program
2.2 Configuring the PC Station
2.3 Configuring the S7 Connection
2.3.1 Adding the S7 Connection
2.3.2 Displaying and Changing Properties of the S7 Connection in the Inspector Window
2.4 Compiling and Downloading the Configuration and User Program of the S7-1200
2.5 Compiling and Downloading the PC Station Configuration
2.6 OPC Scout V10
3 Procedure for S7-1200 V4 and Higher
3.1 Configuration of the S7-1200
3.1.1 Configure the Hardware
3.1.2 Create a User Program
3.2 Configuration of the PC Station
3.3 Configure the S7 Connection
3.3.1 Add the S7 Connection
3.3.2 Display and Change Properties of the S7 Connection in the Inspector Window
3.4 Compile and Download the Configuration and User Program of the S7-1200
3.5 Compile and Download the PC Station Configuration
3.6 OPC Scout V10
3.6.1 Establish Connection to the OPC Server
3.6.2 Symbolic Access
FAQ 07/2015 Connecting a PC Station to an S7-1200 using OPC TIA Portal https://support.industry.siemens.com/cs/ww/en/view/39960679
Security informa- tion This entry is from the Siemens Industry Online Support. The general terms of use (http://www.siemens.com/terms_of_use) apply. Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product- specific newsletter. For more information, visit http://support.automation.siemens.com. d e v r e s e r s t h g i r l l A 5 1 0 2 G A s n e m e S i Connectiong a PC Station to an S7-1200 using OPC Entry-ID: 39960679, V1.2, 07/2015 2
Contents 1 2 3 d e v r e s e r s t h g i r l l A 5 1 0 2 G A s n e m e S i 2.4 Introduction ........................................................................................................ 4 Procedure for S7-1200 up to firmware V3 ....................................................... 5 Configuration of the S7-1200 ............................................................... 7 2.1 Configuring the Hardware .................................................................... 7 2.1.1 Creating a User Program ................................................................... 10 2.1.2 2.2 Configuring the PC Station ................................................................. 13 Configuring the S7 Connection .......................................................... 20 2.3 Adding the S7 Connection.................................................................. 20 2.3.1 Displaying and Changing Properties of the S7 Connection in the 2.3.2 Inspector Window ............................................................................... 21 Compiling and Downloading the Configuration and User Program of the S7-1200 ..................................................................... 22 Compiling and Downloading the PC Station Configuration ................ 25 2.5 OPC Scout V10 .................................................................................. 31 2.6 Procedure for S7-1200 V4 and Higher ........................................................... 35 Configuration of the S7-1200 ............................................................. 37 3.1 Configure the Hardware ..................................................................... 37 3.1.1 3.1.2 Create a User Program ...................................................................... 42 Configuration of the PC Station .......................................................... 46 3.2 Configure the S7 Connection ............................................................. 55 3.3 Add the S7 Connection ...................................................................... 55 3.3.1 3.3.2 Display and Change Properties of the S7 Connection in the Inspector Window ............................................................................... 56 Compile and Download the Configuration and User Program of the S7-1200 ........................................................................................ 59 Compile and Download the PC Station Configuration ....................... 63 OPC Scout V10 .................................................................................. 68 Establish Connection to the OPC Server ........................................... 68 Symbolic Access ................................................................................ 68 3.5 3.6 3.6.1 3.6.2 3.4 Connectiong a PC Station to an S7-1200 using OPC Entry-ID: 39960679, V1.2, 07/2015 3
1 Introduction 1 Introduction This entry shows you how to configure an S7-1200, a PC station and an S7 connection in the TIA Portal so that you can exchange data between the stations over Industrial Ethernet. Note In the TIA Portal you need STEP 7 Professional, because with STEP 7 Basic you cannot configure a PC station, but only the SIMATIC S7-1200. d e v r e s e r s t h g i r l l A 5 1 0 2 G A s n e m e S i Connectiong a PC Station to an S7-1200 using OPC Entry-ID: 39960679, V1.2, 07/2015 4
2 Procedure for S7-1200 up to firmware V3 2 Procedure for S7-1200 up to firmware V3 This chapter shows: How you configure an SIMATIC S7-1200 and a PC station in TIA Portal How you project an S7 connection for data exchange between SIMATIC S7-1200 and PC station Creating a Project In Windows, select the command "Start > All Programs > Siemens Automation > TIA Portal V12" to start the TIA Portal. In the Portal view, select the "Create new project" action. Enter the project name in the appropriate field. Figure 2-1 d e v r e s e r s t h g i r l l A 5 1 0 2 G A s n e m e S i Click the "Create" button to create a new project. Figure 2-2 Connectiong a PC Station to an S7-1200 using OPC Entry-ID: 39960679, V1.2, 07/2015 5
2 Procedure for S7-1200 up to firmware V3 Switch to Project View Use the "Project View" link to switch to the Project View. Figure 2-3 d e v r e s e r s t h g i r l l A 5 1 0 2 G A s n e m e S i Connectiong a PC Station to an S7-1200 using OPC Entry-ID: 39960679, V1.2, 07/2015 6
2 Procedure for S7-1200 up to firmware V3 2.1 Configuration of the S7-1200 You configure your S7-1200 station in the TIA Portal. Then you create the user program and define which data is to be monitored over the S7 connection of the OPC server. 2.1.1 Configuring the Hardware Add an S7-1200 Station In the project tree, double-click the "Add new device" item. The "Add new device" dialog opens. Figure 2-4 d e v r e s e r s t h g i r l l A 5 1 0 2 G A s n e m e S i Click the "Controllers" button in the working area. Go to "Controllers > SIMATIC S7-1200 > CPU" and select the required controller. Click the "OK" button to add the selected S7-1200 CPU to your project. Connectiong a PC Station to an S7-1200 using OPC Entry-ID: 39960679, V1.2, 07/2015 7
2 Procedure for S7-1200 up to firmware V3 Figure 2-5 d e v r e s e r s t h g i r l l A 5 1 0 2 G A s n e m e S i Define IP address and assign subnet In the project tree, double-click the "Devices & networks" item. The devices and networks editor opens. Connectiong a PC Station to an S7-1200 using OPC Entry-ID: 39960679, V1.2, 07/2015 8