SPECIFICATION SHEET FOR Cl2 Sensor TYPE Cl2/M-20
SPECIFICATION SHEET FOR Cl2 Sensor TYPE Cl2/M-20
深 圳 市 逸 云 天 电 子 有 限 公 司 SPECIFICATION SHEET FOR Cl2 Sensor TYPE Cl2/M-20 PERFORMANCE CHARACTERISTICS 0 – 20 ppm 200 ppm 2 years in air - 600 ± 150 nA/ppm 0,1 ppm - 20 °C to 45 °C Atmospheric ± 10% No data < 30 sec 15 % to 90 % R.H. non-condensing < 0,2 ppm - 0,4 ppm < 2% signal loss/month 10 – 33 Ohm Not required < 2 % of signal Linear Reading 0 ppm 0 ppm 0 ppm 0 ppm ~ 20 ppm ND Nominal Range Maximum Overload Expected Operation Life Output Signal Resolution Temperature Range Pressure Range Pressure Coefficient T80 Response Time Relative Humidity Range Typical Baseline Range (pure air, 20°C) Maximum Zero Shift (+20°C to +40°C) Long Term Output Drift Recommended Load Resistor Bias Voltage Repeatability Output Linearity CROSS-SENSITIVITY DATA Interfering Gas Concentration 300 ppm 5 ppm 35 ppm 300 ppm 20 ppm CO SO2 NO H2 NO2 H2S Performance data conditions: 20 °C, 50% RH and 1013 mbar APPLICATIONS Continuous Air Quality Monitoring Safety and Environmental Control For Portable Gas Detectors PHYSICAL CHARACTERISTICS Weight Position Sensitivity Storage Life Recommended Storage Temperature Warranty Period ~ 5.4 g None Six months in container 5 °C – 20 °C 12 months from date of dispatch Miniature-Size Outline Dimensions BOTTOM VIEW Reference Sensing Counter 13.5 mm PCD 90° 18 mm 20 mm SIDE VIEW 5 mm Pin Projection 1.5 mm Pins on 13.5 mm PCD REV.: 5/2005 地址:深圳市南山区南头路嘉南美地 E 座 1305 室 电话:0755-86211867 86211857 主页:www.yiyuntian.net Page 1 of 2 联系人:崔 殿 传 真:0755-86211864 邮 箱:info@yiyuntian.net
深 圳 市 逸 云 天 电 子 有 限 公 司 SPECIFICATION SHEET FOR Cl2 Sensor TYPE Cl2/M-20 TEMPERATURE DEPENDENCE The output of an electrochemical sensor varies with temperature. The graphs below show the variation in output with temperature for this type of sensor. The results are shown in the graphs as a mean for a batch of sensors, along with confidence intervals corresponding to ±3 times the standard deviation. The sensitivity dependence is expressed as a percentage of the signal at 20 °C. Sensitivity Temperature Dependence Mean +3SD -3SD ) C ° 0 2 o t d e c n e r e f e r ( t u p t u O 110% 100% 90% 80% 70% 60% 50% -20 -10 0 10 20 30 40 Temperature (°C) The baseline is virtually not affected by changes in temperature. The data contained in this document is for guidance only. Membrapor AG accepts no liability for any consequential losses, injury or damage resulting from the use of this document or the information contained within it. The data is given for guidance only. Customers should test under their own conditions, to ensure that the sensors are suitable for their own requirements. REV.: 5/2005 地址:深圳市南山区南头路嘉南美地 E 座 1305 室 电话:0755-86211867 86211857 主页:www.yiyuntian.net Page 2 of 2 联系人:崔 殿 传 真:0755-86211864 邮 箱:info@yiyuntian.net
分享到:
收藏