s Which IO controller support the functions IRT, prioritized startup, MRP, PROFIenergy, Shared device, I device, Isochronous mode and System redundancy in STEP 7 V5.5? Entry-ID: 44383954 Module Order number 6GK1161-6AA01 6GK1161-6AA02 6GK1160-4AA00 6GK1160-4AA01 6ES7412-2EK06-0AB0 6ES7414-3EM05-0AB0 6ES7414-3EM06-0AB0 6ES7414-3FM06-0AB0 6ES7416-3ER05-0AB0 6ES7416-3ES06-0AB0 6ES7416-3FR05-0AB0 6ES7416-3FS06-0AB0 6ES7412-5HK06-0AB0 6ES7414-5HM06-0AB0 6ES7416-5HS06-0AB0 6ES7417-5HT06-0AB0 PC CPs CP 1616 CP 1616 CP 1604 CP 1604 SIMATIC NET PC software SOFTNET PROFINET IO 6GK1704-1HWxx-3AA0 S7-400 CPUs CPU 412-2PN CPU 414-3PN/DP CPU 414-3PN/DP CPU 414F-3PN/DP CPU 416-3PN/DP CPU 416-3PN/DP CPU 416F-3PN/DP CPU 416F-3PN/DP CPU 412-5H PN/DP CPU 414-5H PN/DP CPU 416-5H PN/DP CPU 417-5H PN/DP S7-300 CPUs CPU 314C-2 PN/DP CPU 315-2PN/DP CPU 315-2PN/DP CPU 315F-2PN/DP CPU 315F-2PN/DP CPU 315T-3PN/DP CPU 317-2PN/DP CPU 317-2PN/DP CPU 317F-2PN/DP CPU 317F-2PN/DP CPU 317T-3PN/DP CPU 317TF-3PN/DP CPU 319-3PN/DP CPU 319-3PN/DP CPU 319F-3PN/DP CPU 319F-3PN/DP 6GK7314-6EH04-0AB0 6ES7315-2EH13-0AB0 6ES7315-2EH14-0AB0 6ES7315-2FH13-0AB0 6ES7315-2FJ14-0AB0 6ES7315-7TJ10-0AB0 6ES7317-2EK13-0AB0 6ES7317-2EK14-0AB0 6ES7317-2FK13-0AB0 6ES7317-2FK14-0AB0 6ES7317-7TK10-0AB0 6ES7317-7UL10-0AB0 6ES7318-3EL00-0AB0 6ES7318-3EL01-0AB0 6ES7318-3FL00-0AB0 6ES7318-3FL01-0AB0 IRT prioritized startup MRP PROFIenergy Shared device I device Isochronous mode System redundancy Link to Product information from V2.0 from V2.2.0 from V2.2.0 from V2.0 from V2.2.0 from V2.2.0 from V2.0 from V2.2.0 from V2.2.0 from V2.0 from V2.2.0 from V2.2.0 from V2.5.2 from V2.5.2 from V2.5.2 from V2.5.2 from V2.5 from V2.5 from V2.5 from V2.5 from V2.5.2 from V2.5.2 from V2.5.2 from V2.5.2 − − − from V8.2 from V8.1 from V8.1 yes yes yes yes − from V6.0 from V5.2 from V6.0 from V6.0 from V5.2 from V6.0 from V5.2 from V6.0 from V6.0 from V5.2 from V6.0 from V6.0 from V5.2 from V6.0 from V5.2 from V6.0 − − − − − − − − from V3.3 − from V3.3 − from V3.2 − from V3.2 − from V3.2 from V3.2 − from V3.2 − from V3.2 from V3.2 from V3.2 from V2.7 from V3.2 from V2.7 from V3.2 from V3.2 from V3.2 − from V3.2 − from V3.2 from V3.2 from V3.2 from V2.7 from V3.2 from V2.7 from V3.2 from V6.0 − from V6.0 from V6.0 − from V6.0 − from V6.0 from V6.0 from V6.0 from V6.0 from V6.0 from V3.3 − from V3.2 − from V3.2 from V3.2 − from V3.2 − from V3.2 from V3.2 from V3.2 − from V3.2 − from V3.2 from V6.0 from V5.0 from V6.0 from V6.0 from V5.0 from V6.0 from V5.0 from V6.0 − − − − from V3.3 from V2.5 from V3.1 from V2.5 from V3.1 from V3.2 from V2.5 from V3.1 from V2.5 from V3.1 from V3.2 from V3.2 from V2.5 from V3.2 from V2.5 from V3.2 from V6.0 from V6.0 − from V6.0 from V6.0 − − from V6.0 from V6.0 − from V6.0 from V6.0 − from V6.0 from V6.05) from V6.05) from V6.05) from V6.05) from V3.3 − from V3.2 − from V3.2 from V3.2 − from V3.2 − from V3.2 from V3.2 from V3.2 − from V3.2 − − from V6.0 − − − − from V3.3 − from V3.2 − from V3.2 from V3.2 − from V3.2 − from V3.2 from V3.2 from V3.2 − from V3.2 − from V3.2 from V3.2 from V6.02) from V6.02) from V6.01)2) from V6.02) − from V6.01)2) − − − − − − − − − − − − from V3.32) from V3.22) from V3.21)2) from V3.22) from V3.22) from V3.21)2) from V3.22) from V3.21)2) from V3.22) from V3.21)2) − − − − − − − − − − − − − from V6.0 from V6.0 from V6.0 from V6.0 − − − − − − − − − − − − − − − − https://support.industry.siemens.com/cs/ww/en/pv/6GK1161-6AA02 https://support.industry.siemens.com/cs/ww/en/pv/6GK1160-4AA01 https://support.industry.siemens.com/cs/ww/en/pv/6ES7412-2EK06-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7414-3EM05-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7414-3EM06-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7414-3EM06-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7416-3ER05-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7416-3ES06-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7416-3FR05-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7416-3FS06-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7412-5HK06-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7414-5HM06-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7416-5HS06-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7417-5HT06-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7314-6EH04-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7315-2EH13-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7315-2EH14-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7315-2FH13-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7315-2FJ14-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7315-7TJ10-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7317-2EK13-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7317-2EK14-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7317-2FK13-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7317-2FK13-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7317-7TK10-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7317-7UL10-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7318-3EL00-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7318-3EL01-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7318-3FL00-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7318-3FL01-0AB0 Change date: 04.03.2015 This entry is from the Service&Support portal of Siemens AG, Siemens Industry Online Support. The general terms of use (http://www.siemens.com/terms_of_use) apply. Page: 1/2
s Which IO controller support the functions IRT, prioritized startup, MRP, PROFIenergy, Shared device, I device, Isochronous mode and System redundancy in STEP 7 V5.5? Entry-ID: 44383954 Module Order number Industrial Ethernet CPs CP 343-1 Standard CP 343-1 Advanced CP 343-1 Advanced CP 443-1 Standard4) CP 443-1 Standard4) CP 443-1 Advanced4) CP 443-1 Advanced4) ET 200S IM151-8 PN/DP CPU IM151-8 PN/DP CPU IM151-8F PN/DP CPU IM151-8F PN/DP CPU ET 200pro IM 154-8 CPU IM 154-8 CPU IM 154-8F CPU IM 154-8FX CPU Embedded und PC-based Automation WinAC RTX 2009 WinAC RTX F 2009 WinAC RTX 2010 WinAC RTX F 2010 S7-mEC EC31-RTX S7-mEC EC31-RTX F S7-mEC EC31-HMI/RTX 6GK7343-1EX30-0XE0 6GK7343-1GX30-0XE0 6GK7343-1GX31-0XE0 6GK7443-1EX20-0XE0 6GK7443-1EX30-0XE0 6GK7443-1GX20-0XE0 6GK7443-1GX30-0XE0 6ES7151-8AB00-0AB0 6ES7151-8AB01-0AB0 6ES7151-8FB00-0AB0 6ES7151-8FB01-0AB0 6ES7154-8AB00-0AB0 6ES7154-8AB01-0AB0 6ES7154-8FB01-0AB0 6ES7154-8FX00-0AB0 6ES7671-0RC07-0YA0 6ES7671-1RC07-0YA0 6ES7671-0RC08-0YA0 6ES7671-1RC08-0YA0 6ES7677-1DD10-0BB0 6ES7677-1FD10-0FB0 6ES7677-1DD10-0BF0 6ES7677-1DD10-0BH0 6ES7677-1DD10-0BG0 IRT prioritized startup − from V1.0 from V3.0 from V2.0 from V3.0 from V2.0 from V3.0 from V2.7 from V3.2 from V2.7 from V3.2 − from V3.2 from V3.2 from V3.2 from V2.2 from V1.0 from V3.0 from V2.0 from V3.0 from V2.0 from V3.0 from V2.7 from V3.2 from V2.7 from V3.2 − from V3.2 from V3.2 from V3.2 yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes MRP PROFIenergy Shared device I device Isochronous mode System redundancy Link to Product information from V2.2 from V1.0 from V3.0 from V2.0 from V3.0 from V2.0 from V3.0 − from V3.2 − from V3.2 − from V3.2 from V3.2 from V3.2 − − yes3) yes3) yes yes yes yes yes from V3.0 − from V3.0 from V2.1 from V3.0 from V2.1 from V3.0 from V2.7 from V3.2 from V2.7 from V3.2 from V2.5 from V3.2 from V3.2 from V3.2 yes yes yes yes yes yes yes yes yes from V2.4 from V1.2 from V3.0 from V2.1 from V3.0 from V2.1 from V3.0 − from V3.2 − from V2.4 from V1.2 from V3.0 − − − − − from V3.2 − from V3.2 from V3.2 − from V3.2 from V3.2 from V3.2 − from V3.2 from V3.2 from V3.2 − − yes yes yes yes yes yes yes − − − − − − − − − − − − − − − − − − from V3.22) from V3.21)2) − from V3.22) from V3.21)2) from V3.21)2) − − yes3) yes3) yes yes yes yes yes − − − − − − − − − − − − − − − − − − − − − − − − https://support.industry.siemens.com/cs/ww/en/pv/6GK7343-1EX30-0XE0 https://support.industry.siemens.com/cs/ww/en/pv/6GK7343-1GX30-0XE0 https://support.industry.siemens.com/cs/ww/en/pv/6GK7343-1GX31-0XE0 https://support.industry.siemens.com/cs/ww/en/pv/6GK7443-1EX20-0XE0 https://support.industry.siemens.com/cs/ww/en/pv/6GK7443-1EX30-0XE0 https://support.industry.siemens.com/cs/ww/en/pv/6GK7443-1GX20-0XE0 https://support.industry.siemens.com/cs/ww/en/pv/6GK7443-1GX30-0XE0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7151-8AB00-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7151-8AB01-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7151-8FB00-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7151-8FB01-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7154-8AB00-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7154-8AB01-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7154-8FB01-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7154-8FX00-0AB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7671-0RC07-0YA0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7671-1RC07-0YA0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7671-0RC08-0YA0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7671-1RC08-0YA0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7677-1DD10-0BB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7677-1FD10-0FB0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7677-1DD10-0BF0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7677-1DD10-0BH0 https://support.industry.siemens.com/cs/ww/en/pv/6ES7677-1DD10-0BG0 1) If you use a F-CPU as PROFINET IO-Controller, the "Failsafe" function and "Isochronous mode" function should not take place together in one IO device. 2) The CPU supports the "Isochronous mode" function only as IO controller. 3) The function is only supported over CP 1616 or CP 1604. 4) With S7-400 Industrial Ethernet CPs the PROFINET functions don`t only depend on the firmware version of the module, but also on the adopted CPU and their firmware version. This is described in the manual of the relevant Industrial Ethernet CP. 5) The function is only supportd in single mode. Change date: 04.03.2015 This entry is from the Service&Support portal of Siemens AG, Siemens Industry Online Support. The general terms of use (http://www.siemens.com/terms_of_use) apply. Page: 2/2
分享到:
收藏